PMRPBX-DATI offers all features of PMRPBX radio-telephone interface and allows to manage and explicitly identify lone worker alarms and failsafe monitoring from 10 handheld radios..
The alarm processing is fully customisable. It will then be possible to define cycles to send alarm messages in speech-synthesis to the radio, or to a list of phone numbers, or to close two independent dry contacts.
Enabling or disabling the failsafe mode is done by sending a specific 5-tone code to each handheld radio. A cyclic polling of each station is also configurable. A timer (configurable individually) allows to manage the return call for each station. In that fails, the alarm cycle (previously defined) is activated.

Other options :
Management of 50 guard tour points in real time, with time-stamping
Software to archive events in daily report files

|
1 opto-isolated input |
1 or 2 telephone lines Power : 12 V (10 to 16 V DC) Consumption: max 100 mA / module DIN-rail mounted Dim max : H114 x L100 x P152 Operating Temperature : - 10°C à + 55°C |